Introduction
1-117SA6 Manual
C53000-G1176-C133-1
Voltage
Protection
(optional)
Overvoltage and undervoltage detection with different stages
Two overvoltage stages for the phase-earth voltages, with common time delay
Two overvoltage stages for the phase-phase voltages, with common time delay
Two overvoltage stages for the symmetrical positive sequence system of the
voltages, with a time delay each
Two overvoltage stages for the symmetrical negative sequence system of the
voltages, with a time delay each
Two overvoltage stages for the zero sequence system of the voltages or any other
single-phase voltage, with a time delay each
Settable drop-off to pick-up ratios for the overvoltage protection functions
Two undervoltage stages for the phase-earth voltages with common time delay
Two undervoltage stages for the phase-phase voltages with common time delay
Two undervoltage stages for the symmetrical positive sequence system of the
voltages, with a time delay each
Settable current criterion for undervoltage protection functions
Fault Location Initiated by trip command or reset of the fault detection;
Computation of the distance to fault with dedicated measured value registers;
Fault location output in ohm, kilometers or miles and % of line length;
Parallel line compensation can be selected;
Optional function; taking into consideration the load current in case of single-phase
earth faults fed from both sides
Fault location output as BCD-code or analog value (dependent on the order variant)
Circuit Breaker
Failure Protection
(optional)
With independent current stages for monitoring current flow through every pole of
the circuit breaker;
With independent monitoring time steps for single-pole and three-pole tripping;
Start by trip command of every internal protection function;
Start by external trip functions possible;
Single or two stages
Short drop off and overshoot times.
Thermal Overload
Protection
(optional)
Thermal display of ohmic loss of the protected object
R. m. s. measurement for all three phase currents
Settable thermal and current alarm stages
Analog Outputs
(optional)
Output of up to four analog values (dependent on the order variant) is possible:
measured values, fault location, breaking earth fault current
User Defined Logic
Functions
Freely programmable combination of internal and external signals for the
implementation of user defined logic functions;
All common logic functions;

Table of Contents

Other manuals for Siemens siprotec 7SA6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens siprotec 7SA6 and is the answer not in the manual?

Siemens siprotec 7SA6 Specifications

General IconGeneral
BrandSiemens
Modelsiprotec 7SA6
CategoryRelays
LanguageEnglish

Related product manuals