Appendix
B-25
7SA6 Manual
C53000-G1176-C133-1
371 >CB1 READY (for AR,CB-Test)
(>CB1 Ready)
Power System
Data 2
SP * * LED BI BO 150 71 1 GI
378 >CB faulty (>CB faulty) Power System
Data 2
SP * * LED BI BO
379 >CB aux. contact 3pole Closed (>CB
3p Closed)
Power System
Data 2
SP * * LED BI BO 150 78 1 GI
380 >CB aux. contact 3pole Open (>CB
3p Open)
Power System
Data 2
SP * * LED BI BO 150 79 1 GI
381 >Single-phase trip permitted from
ext.AR (>1p Trip Perm)
Power System
Data 2
SP ON
OFF
* LED BI BO
382 >External AR programmed for
1phase only (>Only 1ph AR)
Power System
Data 2
SP ON
OFF
* LED BI BO
383 >Enable all AR Zones / Stages
(>Enable ARzones)
Power System
Data 2
SP ON
OFF
ON
OFF
LED BI BO
385 >Lockout SET (>Lockout SET) Power System
Data 2
SP ON
OFF
* LED BI BO 150 35 1 GI
386 >Lockout RESET (>Lockout
RESET)
Power System
Data 2
SP ON
OFF
* LED BI BO 150 36 1 GI
395 >I MIN/MAX Buffer Reset (>I Min-
Max Reset)
Min/Max Mea-
surement Setup
SP ON * LED BI BO
396 >I1 MIN/MAX Buffer Reset (>I1
MiMaReset)
Min/Max Mea-
surement Setup
SP ON * LED BI BO
397 >U MIN/MAX Buffer Reset (>U
MiMaReset)
Min/Max Mea-
surement Setup
SP ON * LED BI BO
398 >Uphph MIN/MAX Buffer Reset
(>UphphMiMaRes)
Min/Max Mea-
surement Setup
SP ON * LED BI BO
399 >U1 MIN/MAX Buffer Reset (>U1
MiMa Reset)
Min/Max Mea-
surement Setup
SP ON * LED BI BO
400 >P MIN/MAX Buffer Reset (>P MiMa
Reset)
Min/Max Mea-
surement Setup
SP ON * LED BI BO
401 >S MIN/MAX Buffer Reset (>S MiMa
Reset)
Min/Max Mea-
surement Setup
SP ON * LED BI BO
402 >Q MIN/MAX Buffer Reset (>Q
MiMa Reset)
Min/Max Mea-
surement Setup
SP ON * LED BI BO
403 >Idmd MIN/MAX Buffer Reset
(>Idmd MiMaReset)
Min/Max Mea-
surement Setup
SP ON * LED BI BO
404 >Pdmd MIN/MAX Buffer Reset
(>Pdmd MiMaReset)
Min/Max Mea-
surement Setup
SP ON * LED BI BO
405 >Qdmd MIN/MAX Buffer Reset
(>Qdmd MiMaReset)
Min/Max Mea-
surement Setup
SP ON * LED BI BO
406 >Sdmd MIN/MAX Buffer Reset
(>Sdmd MiMaReset)
Min/Max Mea-
surement Setup
SP ON * LED BI BO
407 >Frq. MIN/MAX Buffer Reset (>Frq
MiMa Reset)
Min/Max Mea-
surement Setup
SP ON * LED BI BO
408 >Power Factor MIN/MAX Buffer
Reset (>PF MiMaReset)
Min/Max Mea-
surement Setup
SP ON * LED BI BO
410 >CB1 aux. 3p Closed (for AR, CB-
Test) (>CB1 3p Closed)
Power System
Data 2
SP * * LED BI BO 150 80 1 GI
F.No. Description Function Type of
Information
Log-Buffers Configurable in Matrix IEC 60870-5-103
Event Log On/Off
Trip (Fault) Log On/Off
Ground Fault Log On/Off
Marked in Oscill. Record
LED
Binary Input
Function Key
Binary Output
Chatter Blocking
Type
Information-No
Data Unit (ASDU)
General Interrogation