1. SYMPTOM CHART
Symptom Repair order Reference
None of the functions of keyless entry
system operate.
1. Check the transmitter battery. <Ref. to SL-16, CHECK TRANSMIT-
TER BATTERY, INSPECTION, Key-
less Entry System.>
2. Check the fuse. <Ref. to SL-16, CHECK FUSE,
INSPECTION, Keyless Entry Sys-
tem.>
3. Check the keyless entry control module power
supply and ground circuit.
<Ref. to SL-17, CHECK POWER
SUPPLY AND GROUND CIRCUIT,
INSPECTION, Keyless Entry Sys-
tem.>
4. Replace the keyless entry control module. <Ref. to SL-39, Keyless Entry Control
Module.>
The transmitter cannot be registered. 1. Check the transmitter battery. <Ref. to SL-16, CHECK TRANSMIT-
TER BATTERY, INSPECTION, Key-
less Entry System.>
2. Check the registration connector circuit. <Ref. to SL-17, CHECK REGISTRA-
TION CONNECTOR CIRCUIT,
INSPECTION, Keyless Entry Sys-
tem.>
3. Check the door lock switch and circuit. <Ref. to SL-18, CHECK DOOR
SWITCH, INSPECTION, Keyless
Entry System.>
4. Replace the keyless entry control module. <Ref. to SL-39, Keyless Entry Control
Module.>
The door lock or unlock does not
operate.
N
TE:
If the door lock control system does
not operate when using the door lock
switch, check the door lock control
system. <Ref. to SL-9, INSPECTION,
Door Lock Control System.>
1. Check the transmitter battery. <Ref. to SL-16, CHECK TRANSMIT-
TER BATTERY, INSPECTION, Key-
less Entry System.>
2. Make sure the registration connector is not
connected.
Make sure the registration connector
is not connected because keyless
entry system does not operate during
the registration connector connected.
3. Check the key warning switch. <Ref. to SL-19, CHECK KEY WARN-
ING SWITCH, INSPECTION, Keyless
Entry System.>
4. Check the door switch. <Ref. to SL-18, CHECK DOOR
SWITCH, INSPECTION, Keyless
Entry System.>
5. Check output signal to double lock module.
(With double lock)
<Ref. to SL-21, CHECK OUTPUT
SIGNAL TO DOUBLE LOCK MOD-
ULE, INSPECTION, Keyless Entry
System.>
6. Replace the keyless entry control module. <Ref. to SL-39, Keyless Entry Control
Module.>
The hazard light does not operate. 1. Check the hazard light operation. <Ref. to SL-20, CHECK HAZARD
LIGHT OPERATION, INSPECTION,
Keyless Entry System.>
2. Replace the keyless entry control module. <Ref. to SL-39, Keyless Entry Control
Module.>