Supermicro SSE-F3548S/SSE-F3548SR Configuration User’s Guide
125
The MTU, VLAN and spanning tree parameters of a port channel interface will be used on its
member ports. After adding a port to any port channel, users should not configure MTU,
VLAN and spanning tree parameters on that port. Instead users should configure MTU, VLAN
and spanning tree parameters on the port channel interfaces.
The examples below show various ways to create port channels.
Create an LACP port channel with member ports cx 0/1 and cx 0/2.
SMIS# configure terminal
SMIS(config)# interface port-channel 10
SMIS(config-if)# exit
SMIS(config)# int range cx 0/1-2
SMIS(config-if)# channel-group 10 mode active
For LACP aggregation, use the active or
passive mode.
For static link aggregation, use mode
on.
Step 4
End
Exits the interface configuration mode.
Step 5
show interface port-channel <channel-group-
Displays the configured port channel
number>
information.
show etherchannel [[channel-group-number] {
detail | load-balance | port | por
t-channel | summary | protocol}]
Step 6
write startup-config
Optional step saves this port channel
configuration to be part of startup
configuration.