Supermicro SSE-F3548S/SSE-F3548SR Configuration User’s Guide
124
Only ports of same speed can be added to port channel interfaces.
Follow the steps below to add member ports to port channel interfaces.
Step
Command
Description
Step 1
configure terminal
Enters the configuration mode
Step 2
interface <interface-type><interface-id>
Enters the interface mode.
Or
interface range <interface-type><interface-id>
interface-type may be any of the
following:
fx-ethernet fx
cx-ethernet cx
interface-id is in slot/port format for
all
physical interfaces.To configure
multiple interfaces, use
the “interface
range …” command. To
provide
a range,
use a hyphen (-).
between the start and
end interfacenumbers. E.g.: int range fx
0/1-10 To provide multiple interfaces
or
ranges, separate with a comma (,).E.g.:
int range fx 0/1-10, fx 0/20
Step 3
channel-group <channel-group-number> mode
Configures the interfaces as member
{active | passive | on}
ports for the given port channel.
channel-group-number The port
channel to which these member ports
are added.

Table of Contents