Note
The SBC signal has to provided as well when the voltage shall be switched on with Node Safety or
Circulo
3.1.3.2.3 Limitations
Please note that the brake phase voltage control comes with limited accuracy.
Use this feature only in low precision applications (e.g. load-dependant speed of a fan).
3.1.3.2.3.1 Parameters
0x2004 Brake Release Release strategy can be used to activate the voltage on the brake output, Brake
options: Brake status turns it On and Off, Brake options: Output voltage sets the voltage.