3.1.9.1.47 0x200B Max power
This object is a limit on maximum mechanical power on motor shaft. Wrong settings of "motor torque
constant", "position sensor configurations" or "number of motor pole-pairs" can lead to misbehavior of
power limitation feature. By default the power of each Drive is internally limited to 110% of its Maximum
Peak Output Power value. As a result, this object will only be effective if its value is less than 110% of the
drive's Maximum Peak Output Power.
Name Index:Sub Type Bit
Size
Min
Data
Max Data Default
Data
Unit Access PDO
Mapping
Max
power
0x200B:0 UDINT 32 1 2147483647 2147483647 W readwrite
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.19.0 | Built 2022-02-01 776/1031