235
Inspection, Repair
Chapter 10
1
2
3
4
5
6
7
8
9
10
11
PT10
5. Inspection, Repair
Before inspection, be sure to turn off the original power supply. Some circuits are still
applied voltage eve if the original power supply was turned off. Wait until these circuits are
completely out of voltage (4 minutes) and then start working.
Inspection Point Action Inspection Cycle
Attaching of each type of cover Attach all the covers.
At start of working
Setting condition of embroidery
thread
Set it correctly.
Check breakage and/or bent of
needle.
Replace the needle.
Lubricating condition of each
section
Lubricate.
Automatic lubrication system Refill oil.
Belt tension (main shaft, X/Y
drive system)
Consult the distributor. Once/3 months
Before repairing the machine, be sure to turn off the original power supply. Some circuits
are still applied voltage eve if the original power supply was turned off. Wait until these
circuits are completely out of voltage (4 minutes) and then start working.
If the machine needs the repair, the repair must be done only by the service personnel
assigned and trained by Tajima or qualified technician. (Consult your distributor.) Do not
change the specification nor modify the parts of the machine without due consultation with
Tajima. Such modification may have the risk against the operational safety.
When restarting the machine after repairs, attach all covers etc. which were removed for
repair operation.
For the repair, use Tajima genuine parts for replacement.