2.3.3 Heating
Ordering option 3 defines if the sensor is equipped with extra heating for demanding
environmental conditions. Option 4 providing full sensor heating is best suited for most
demanding environments.
Power consumption requirement depends on the selected heating option.
Table 7 Heating
Option Heating
1 Non-heated
2 Heated transducers (Min. 30 W power supply is needed)
3 Heated transducers and arms (Min. 150 W needed)
4 Heated transducers, arms, and body (Min. 250 W needed)
Vaisala recommends using heated versions of WMT700 in environmental conditions
where snow and ice build-up is possible.
2.3.4 Digital Communication Interface
Ordering option 4 defines the serial line physical interface. Four dierent standard
communication interfaces are available. In addition, there is a service port.
Table 8 Digital Communication Interface
Option Hardware Interface
A RS-485 isolated (1 pair)
B RS-422 isolated
C RS-232 isolated
D SDI-12 isolated
To change the product version characteristics listed in Table 8 (page 20), contact Vaisala
Service Center.
WMT700 User Guide M211095EN-H
20

Table of Contents

Other manuals for Vaisala WINDCAP WMT700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaisala WINDCAP WMT700 Series and is the answer not in the manual?

Vaisala WINDCAP WMT700 Series Specifications

General IconGeneral
BrandVaisala
ModelWINDCAP WMT700 Series
CategoryAccessories
LanguageEnglish

Related product manuals