EasyManua.ls Logo

Vaisala WINDCAP WMT700 Series - Cables; Table 17 Cables

Vaisala WINDCAP WMT700 Series
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The optional WMT700 zero wind verifier (WMT70Verifier) is a small echo-free chamber for
testing the mechanical integrity of WMT700 and performing one-point calibration. The
verifier ensures that the array is undamaged and that the transducers are parallel to each
other. You can perform the verifier test also in the field.
2.4.3 Cables
Select the cables according to your operating environment.
Table 17 Cables
Order Code Description Purpose
WMT70Conn Cable connector Cable
227567SP Cable 2 m, cable connector, open leads
on one end
Used for analog output or serial communication
with two serial ports.
227568SP Cable 10 m, cable connector, open leads
on one end
Used for analog output or serial communication
with two serial ports.
237890SP Cable 15 m, cable connector, open leads
on one end
Used for analog output or serial communication
with two serial ports.
237889SP Cable 26 m, cable connector, open leads
on one end
Used for analog output or serial communication
with two serial ports.
228259SP RS-485 cable 2 m, cable connector,
open leads on one end
Used for serial communication with RS-485
interface.
228260SP RS-485 Cable 10 m, cable connector,
open leads on one end
Used for serial communication with RS-485
interface.
227565SP MAWS cable 10 m Used for connecting WMT700 to Vaisala Automatic
Weather Station MAWS.
229807SP AWS520 cable 10 m, shield connected
to PE pin
Used for connecting WMT700 to Vaisala Fixed Site
Observation System AWS520.
227566SP AWS520 cable 10 m, shield not
connected to PE pin
Used for connecting WMT700 to Vaisala Fixed Site
Observation System AWS520.
231425SP ROSA analog cable 10 m, cable
connector, open leads on one end
Used for connecting WMT700 to Vaisala Road
Weather System ROSA.
227569SP Adapter cable for WS425 serial Used for connecting the WS425 cable to WMT700.
Only applicable for retrofit installations.
227570SP Adapter cable for WS425 analog
frequency output
Used for connecting the WS425 cable to WMT700.
Only applicable for retrofit installations.
227571SP Adapter cable for WS425 analog
voltage output
Used for connecting the WS425 cable to WMT700.
Only applicable for retrofit installations.
ASM210719SP Junction Box with Cable 2 meters Used when a cable longer than 10 meters is needed.
Junction Box contains terminal blocks that extend
the 2-meter cable to a needed length.
WMT700 User Guide M211095EN-H