Configuration (page 101)
2.3.1 Measurement Range
Ordering option 1 defines the wind speed operation range. The maximum reported value of
wind speed 40, 65, 75, or 90 m/s, depending on the selected option. Accredited Wind
Calibration according to Measnet procedure.
Table 5 Measurement Ranges of Dierent Sensor Types
Sensor Type Measurement Range
1 WMT701 up to 40 m/s
2 WMT702 up to 65 m/s
3 WMT703 up to 75 m/s
4 WMT704 up to 90 m/s
A WMT701 up to 40 m/s + Accredited Wind Calibration
B WMT702 up to 65 m/s + Accredited Wind Calibration
C WMT703 up to 75 m/s + Accredited Wind Calibration
D WMT704 up to 90 m/s + Accredited Wind Calibration
2.3.2 Temperature Range
Ordering option 2 defines the operating temperature range for the sensor.
Table 6 Temperature Range
Option Temperature Range
A -10 ... +60 °C
B -40 ... +60 °C
C -55 ... +70 °C
The temperature range is not connected to heating in any way. If you operate in a
demanding environment where ice accumulation is expected, Vaisala recommends using a
heated sensor.