EasyManua.ls Logo

Vaisala WINDCAP WMT700 Series - 5.19 Operating WMT700 with Terminal Program

Vaisala WINDCAP WMT700 Series
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.19 Operating WMT700 with Terminal
Program
PC with a serial port.
Required cables for serial connection. See 2.4.3 Cables (page 28).
Any terminal program, such as Tera Term or Windows HyperTerminal.
1. Connect a cable between your terminal computer, power supply, and WMT700.
2. Open the Windows HyperTerminal program.
3. Cancel the new connection.
4. Select File > Properties.
5. Select the correct COM port and select
Configure.
6. Set the communication parameters according to the configured port settings of
WMT700. The default values for WMT700 are:
Bits per second
9600
Data bits 8
Parity None
Stop bits 1
Flow control None
7. Select Apply > OK.
8. Select Settings > ASCII setup > ASCII sending - Send line ends with line feed
(optional) > OK. Close the New Connection Properties window.
9. Select View > Font > Terminal.
10. Select Call > Call. Enter a name and select an icon for the connection. Select OK.
11. Switch the sensor power supply on. The following information is displayed: WMT700
v<version number>
12. Wait for 4 seconds. WMT700 enters measurement mode automatically.
13. To test the connection, enter
configuration mode with the following command:
$0OPEN<CR><LF>
14. Use the following command to return to measurement mode: CLOSE<CR><LF>
You can now start operating WMT700. Note that WMT700 does not send data messages
automatically unless
configured to do so.
WMT700 User Guide M211095EN-H
134

Table of Contents

Other manuals for Vaisala WINDCAP WMT700 Series

Related product manuals