Loading...
5.9.3 Loading Settings from Configuration Files
You can configure configuration of WMT700 settings over the RS-485, RS-422, or RS-232
interface using configuration files. You can send a text file containing the configuration
settings to the sensor with a terminal program, such as Tera Term or Windows
HyperTerminal.
1. Use the G command to fetch the current WMT700 parameters.
2. Disable error messages with the command S messages,0
3. Copy the values from the terminal program to a
file. Remove the parameters you do not
want to change. Also remove the parameter “messages” to avoid switching messaging
on during the transfer.
4. Clear the error counters with the command CLEARERR.
5. Send the
file to WMT700 to change the settings.
Chapter 5 – Operation