4.7.1 Configuring Wind Direction Oset
If you cannot align the sensor so that the arrow points North, make a wind direction oset
by configuring the deviation angle in the sensor.
1. Mount the sensor to the desired position.
2.
Define the deviation angle from the North (zero) alignment.
3. Type the wind message formatting command and the deviation angle S
wndDirOffset,(angle). Indicate the direction from the North line with + or -.
The sensor transmits the wind direction data by using the changed zero alignment.
More Information
Configuration Parameter Descriptions (page 187)
4.7.2
 Analog Output Parameter for WMT700 in Tunnels and
Cranes
Analog outputs can be used in road and rail tunnel applications as well as crane applications.
You can get horizontal and direction data with the parameter aout_map. The aout_map
parameter defines how analog output signals are used. WMT700 provides the following
analog outputs:
aout1 for wind speed data
aout2 for wind direction data
Table 22 
aout_map Values
Parameter Definition
0 aout1, wind speed
aout2, wind direction (default)