EasyManua.ls Logo

Vaisala WINDCAP WMT700 Series - 5.25 WS425 A;B WAT11 Profile

Vaisala WINDCAP WMT700 Series
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Default
Value
Profile-Specific Allowed Values Description
autoSend
0 0 = Automatic messages disabled Automatic data message number.
Selects the data message format
for automatic messages.
com1_protocol
0
1)
3 = WS425 A/B ASCII Profile for serial port COM1
com2_protocol
3 3 = WS425 A/B ASCII Profile for serial port COM2
com2_interf
N/A
2)
0 = RS-485
1 = RS-422
3 = RS-232
Interface for serial port COM2
wndOrientation
0 0 = Array facing up
1 = Array facing down
Orientation of the array of
WMT700
wndUnit
0
2)
0 = Meters per second
1 = Miles per hour
2 = Kilometers per hour
3 = Knots
Wind speed unit
wndVector
0 0 = Scalar averaging Wind averaging method
1) The parameter has no protocol-specific default value. It is determined separately in the configuration code.
2) Wind speed unit and COM2 digital communication interface are defined in the order form. Default setting may be any of the
allowed options, and it can be verified from the unit’s configuration code.
5.24.1 WS425 A/B ASCII Commands
The following commands are available for operating WMT700 with the WS425 A/B ASCII
profile.
Table 53 WS425 A/B ASCII Commands
Command Description
I
Requests identification information for WMT700.
Wx
Starts measurement based on averaging time and fetches the data.
You cannot use the WS425 A/B ASCII command Measurement Unit Change Ux with
WMT700. For a list of configuration commands for WMT700, see A. Command Set for
WMT700 (page 181).
5.24.1.1 I — Identify Sensor
This command shows the vendor, model number, and version information of WMT700.
I
WMT700 User Guide M211095EN-H
148

Table of Contents

Other manuals for Vaisala WINDCAP WMT700 Series

Related product manuals