4. If you removed the mounting adapter, fasten it to the sensor by rotating the adapter
clockwise. Tighten the three screws at the bottom of the sensor.
4.5 Mounting WMT700 on Vertical Pole
Mast
• 5-mm Allen key
• Adjustable wrench
You can mount WMT700 on a 30‑mm (1.18‑in) or a 60‑mm (2.36‑in) pole mast. The
WMT70FIX mounting kit contains U bolts for both kinds of pole masts (2 pcs each).
You can place WMT700 either on the side or on top of the mast. When selecting the
mounting position, take into account:
• Other equipment installed on the mast (for example, air terminal)
• Cable routing (inside or outside the mast)
1. Make sure that the cable is
firmly connected to the sensor.
Chapter 4 – Installation
57