The default error indication is an out-of-range signal that is more than 10 V or 20 mA but
other error settings can also be configured.
Example
To set analog output 1 error indication in voltage mode to 1 V, set the analog output error
value to 1. Use the following command:
S aout1err,1
More Information
‣
Configuration Parameter Descriptions (page 187)
5.17 Operating WMT700 with WS425 and
SDI-12 Profiles
Each communication profile has its own section listing the configurable parameters and the
available commands and data messages.
5.18
Communication Profiles
WMT700 supports the following communication profiles:
• WMT700
• ROSA - MES12
• WS425 - ASCII
• WS425 - NMEA Extended (version 0183)
• WS425 - SDI-12 (version 1.3)
• WS425 - ASOS
The
profile has been preconfigured at the factory according to your requirements specified
when ordering WMT700. You can change the profile through the serial interface, if
necessary.
5.18.1
Changing Communication Profile
The communication profile and other settings have been configured at the factory
according your specifications. You can start using WMT700 directly after the installation
with these settings.
If you want to change the communication profile, you must change all parameters to match
the new
profile.