Test Setup According to
Radiated emissions CISPR 22
RF field immunity IEC 61000-4-3
Insulation resistance IEC 60092-504
1) Limits according to IEC 60945: Maritime navigation and radiocommunication equipment and systems - General requirements
- Methods of testing and required test results. 4th edition, 2002-08. See G. Certificate (page 199)
2.3 Ordering Options
Table 4 Ordering Options
Ordering Option
Number
Ordering Option
1 Measurement range
2 Temperature range
3 Heating
4 Digital communication interface
5 Digital communication profile
6 Digital communication unit
7 Analog output signal for wind speed channel
8 Analog output signal for wind direction channel
9 Connection cables
10 Mounting adapters
11 Not in use
12 Accessories
13 Manuals
If required, you can change:
2.3.4 Digital Communication Interface (page 20)
2.3.5 Digital Communication Profile (page 21)
2.3.6 Digital Communication Units (page 21)
2.3.7 Analog Output Signal for Wind Speed Channel (page 21)
2.3.8 Analog Output Signal for Wind Direction Channel (page 23)
WMT700 User Guide M211095EN-H
18

Table of Contents

Other manuals for Vaisala WINDCAP WMT700 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vaisala WINDCAP WMT700 Series and is the answer not in the manual?

Vaisala WINDCAP WMT700 Series Specifications

General IconGeneral
Measurement PrincipleUltrasonic
Protection ClassIP66
Product TypeWind Sensor
Wind Speed Range0 to 60 m/s
Wind Direction Range0 to 360°
Humidity Range0 to 100% RH
Communication ProtocolSDI-12
HeatingOptional