Use a power supply that has enough power for WMT700. Part of the power is dissipated in
the cables.
Table 31 Sensor Power of Dierent Heating Options
Heating Option Required Sensor Power Parameter Values
Transducers 40 W 0 ... 40
Transducers and arms 200 W 0 ... 200
Transducers, arms, and body 350 W 0 ... 350
4.10.2.3 Body Heating Power Adjustment
The heaBMaxPower parameter sets WMT700 maximum body heater power (in Watts).
You can disable WMT700 body heating by setting the heaBMaxPower parameter value to
0. The default value is 150.
Table 32 heaBMaxPower Parameter Values
Body Heating Parameter Value
O 0
On 150
4.11 Upgrade from WS425 to WMT700
When upgrading to WMT700, there are the following installation options:
Basic installation, which consists of mounting WMT700 with the FIX70 mounting kit
and the WMT700 mounting adapter.
Uninstall the WS425 wind sensor and mounting kit. and follow the installation
instructions in 4.1 Installing WMT700 (page 51).
Retrofit installation, which consists of mounting WMT700 with a WS425 mounting kit
and the WMT700 mounting adapter for FIX30/60.
At the measurement site, mount WMT700 and connect it to the power source and data
acquisition system.
After upgrading to WMT700, you can install the optional bird prevention kit available for the
wind sensor.
WMT700 User Guide M211095EN-H
82