You can only use the user-configurable data messages with the WMT700 protocol.
More Information
‣
Data Messages (page 119)
5.9.1 Configuring Data Messages
After you have defined the new data message, you can test the message by polling it in the
configuration mode. See 5.6.3 POLL — Get Message (page 107).
More Information
‣
POLL — Get Message (page 107)
‣
START — Start Continuous Measurement (page 106)
5.9.1.1 Items for Data Messages
The user-configurable data messages can contain wind measurement, control character,
check sum, and monitoring items. Configure new data messages with the msg1, msg2,
msg3, and msg4 parameters. All available items are listed in the following tables.
Table 40 Wind Measurement Items for Data Messages
Item Description
\ad Address
\dm Wind direction minimum calculated over the averaging period
\dx Wind direction maximum calculated over the averaging period
\gu Wind gust speed
\lu Wind lull speed
\rg Signal quality
\st Speed of sound
\ts Sonic temperature
\tz 10 s average of sonic temperature
\va Validity of the measurement data. The available values are:1 = Valid wind measurement
data0 = Unable to measure
\w1 Wind direction when the peak speed (\wp) occurred
\wd Wind direction, average
\wm Wind speed minimum calculated over the averaging period
\wp Wind speed maximum calculated over the averaging period
WMT700 User Guide M211095EN-H