Setting Parameter WMT700 WS425
ASCII
WS425
NMEA
Ext
WS425
SDI-12
WS425
F/G
ASOS
ROSA
MES12
Automatic
message
port
autoPort
COM1 COM1 COM2 COM1 COM1 COM1
Automatic
data
message
interval
autoInt
1 s 1 s 1 s 1 s 1 s 1 s
Wind
averaging
time
wndAvg
1 s 1 s 3 s 1 s 5 s 600 s
Gust
averaging
time
wndGustTime
3 s 3 s 3 s 3 s 3 s 3 s
Installa-
tion
orienta-
tion of
WMT700
wndOrientation
Array
facing up
Array
facing up
Array
facing up
Array
facing up
Array
facing up
Array
facing up
Wind
measure-
ment
averaging
method
wndVector
Scalar
averaging
Scalar
averaging
Scalar
averaging
Scalar
averaging
Scalar
averaging
Scalar
averaging
The parameters in the following table do not have a protocol-specific default value. They are
defined in the configuration code.
Table 72 Parameters with No
Protocol-specific Default Value
Setting Parameter WMT700 WS425
ASCII
WS425
NMEA
Ext
WS425
SDI-12
WS425
F/G
ASOS
ROSA
MES12
Interface
type
com2Interf
N/A N/A N/A N/A N/A N/A
Wind speed
unit
wndUnit
N/A N/A N/A N/A N/A N/A
WMT700 User Guide M211095EN-H