Loading...
Vaisala recommends that you only use this command for testing data connections. To
fetch measurement data for other purposes, switch the serial port to the measurement
mode. The polling command in the measurement mode depends on the selected profile.
POLL y
y
Identification number for the data message format.
More Information
Data Messages (page 119)
5.6.4
 RESET — Reset CPU
This command resets WMT700.
RESET
5.7
 Information Commands
5.7.1 ? — Display Command Set
This command displays a list of available configuration commands.
?
5.7.2
 H — Display Help and Messages
This command displays a list of supported data messages and their identification numbers
as well as the available values for wind speed measurement unit,
profile, baud rate, interface,
and analog output.
H
5.7.3
 VERSION — Show Firmware Version
This command displays the label and version of the WMT700 software.
WMT700 User Guide M211095EN-H