Service Manual FB 7100 Programming
4 - 72 January, 2005
4.3.8.8 Audit unit Ext/Int
This option is used to shift between the activation of an internal and an
external audit unit.
4.3.8.9 Exact change eq.
This option is used to set parameters for the exact change equation.
4.3.8.10 Exact change offset
This option is used to set parameters for the exact change offset.
v Sel Esc^
Audit unit install.
* Audit unit Ext/Int.
Exact change eq.
Sub menu Description
Audit unit Ext/Int If an external audit unit has been installed, it must
be activated through this option.
Once activated, the external unit will take over all
handling of audit data sent from the coin
mechanism, and at the same time the standard
internal unit will be deactivated.
Select “Ext” to activate the external audit unit.
Select “Int” if you want to deactivate the external
audit unit and go back to using the machine’s
internal audit unit.
v Sel Esc^
Audit unit Ext/Int
* Exact change eq.
Exact change offset
Sub menu Description
Exact change eq. The purpose of the Exact change equation option
is to specify the preconditions for when the coin
unit should switch to “Coin tubes empty” mode
and the vending machine displays “Use exact
change”.
Choose a value between 0 and 15 according to
the combinations of tube empty states as defined
in the manual of the coin unit.
v Sel Esc^
Exact change eq.
* Exact change offset
Keyboard inhibit