Service Manual FB 7100 Event recording and troubleshooting
3 - 6 January, 2005
FB Ing motor t.out
(log book only)
This message indicates that the brewer ingredient motor is not running
correctly. The message “Out of service” appears in credit display.
FB motor error
(log book only)
This message indicates a brewer motor error causing the machine to stop
operating. The message “Out of service” appears in the credit display
FB short circuit
(log book only)
This message indicates a brewer motor error related to the FB print. The
message “Out of service” appears in the credit display.
FB unexp. current
(log book only)
This message indicates an unexpected current from brewer causing the
machine to stop operation. The message “Out of service” appears in the
credit display.
Possible cause Remedy
Calibration error Check calibration of ingredients.
See chap. 4, page 4-64
Hardware error on FB print Check, replace if necessary.
See chap. 5K, page 5K-10
Possible cause Remedy
Defective brewer motor Check brewer motor and brewer
connections. Adjust, repair or replace
defective part if necessary.
See chap. 5B, page 5B-4
Defective harness between FB print
and switches
Defective harness for brewer motor
Defective FB print Check, replace if necessary.
See chap. 5K, page 5K-10
Possible cause Remedy
Defective brewer motor Check motor.
See chap. 5B, page 5B-19
Defective FB print Check, replace print if necessary.
See chap. 5K, page 5K-10
Possible cause Remedy
Defective FB print Check print, replace if necessary.
See chap. 5K, page 5K-10