Service Manual FB 7100 Programming
January, 2005 4- 45
4.2.10.9 Set counters on/off
The Set counters on/off option makes it possible to have the display show
the number of drinks dispensed (resettable and non resettable counters)
during initialization of the machine.
(Initialization = during start up and when returning from menu system to
vend mode.)
4.2.10.10 Selfcheck setting
An automatic check of the software is carried out daily. By default the
check is performed from midnight, but if an other time is preferred, a
starting time can be set via this menu.
v Sel Esc^
Energy saving
* Set counters on/off
Selfcheck setting
Sub menu Description
Set counters on/off Select ‘On’ to have the display show the number
of drinks dispensed.
Select ‘Off’ to turn the function off.
v Sel Esc^
Set counters on/off
* Selfcheck setting
Sub menu Description
Set hours and minutes Enter the starting hour and minutes for the daily
software check.