Status Code Entry Chart (cont.)
Status
Code
E6-00
E6-01
E7-01
E7-02
E9-XX
Fx-xx
Description
Front door interlock switch error
The C button was pressed while a print was
being made in the roll feed mode. An
operator induced soft shutdown results in a
complete print being made. The left side
door must be opened and then closed.
Front door interlock switch error
The Exit button was pressed while a print
was being made in the roil feed mode. An
operator-induced hard shutdown results in a
partial print being made. The left side door
must be opened and then closed.
Communication error
The IOT is unable to communicate with the
ESS. The IOT off-line and media menus will
still function, but cannot print from the ESS
or network.
Printer message display error
A required message is not available in the
language EPROM. Update the language
EPROM.
Software shutdown
This error is of unknown cause. Please
contact Software engineering.
Refer to the Folder Service Manual for ail
F-codes.
Components
instruct the customer as to the
appropriate time to press "C"
Instruct the customer as to the
appropriate time to press "Exit"
Perform GP5 Communication
Loopback Test located in Section 6.
(For the 6830 Folder, refer to the
Folder Communication Test in the
folder service manual.)
Language EPROM
RAP
NO
Comp
Code
[0211]
BSD Ref
2.1
PL
Ref
Status Code Entry Chart
1/98
1-12
8830