February 2013
4-248
ColorQube® 9303 Family
REP 62.4, REP 62.5
Repairs/Adjustments
2. Re-connect the sensor.
3. Install the sensor plate. Ensure that the three locating lugs are correctly located in the
slots of the mounting plate.
4. The replacement of the removed components in the reverse of the removal procedure.
REP 62.5 Scan Carriage Assembly
Parts List on PL 62.15
Removal
WARNING
Switch off the electricity to the machine. Refer to GP 14. Disconnect the power cord
from the customer supply while performing tasks that do not need electricity. Electricity
can cause death or injury. Moving parts can cause injury.
WARNING
Take care during this procedure. Sharp edges may be present that can cause injury.
1. Remove the CVT glass, REP 62.3.
2. Remove the CVT ramp and document glass assembly, REP 62.3.
3. Disconnect the LED exposure lamps ribbon cable, REP 62.11.
4. Figure 1. Remove the scan carriage assembly.