February 2013
6-80
ColorQube® 9303 Family
GP 27
General Procedures/Information
Procedure
WARNING
Take care during this procedure. The registration/preheat assembly will become hot
during normal operation.
1. Run dC969 Clean Ink Smears. Repeat the routine until the output blank sheets are free of
contamination.
2. Make copies as normal and inspect the result for contamination. If contamination is
present repeat dC969.
3. If contamination is still present, switch off the machine, GP 14. Allow the registration / pre-
heat assembly to cool. Refer to REP 89.1, clean the platelets with a cleaning cloth damp-
ened with cleaning fluid.
4. If the registration / preheat assembly has been removed, perform dC625 Registration /
Preheat Calibration.
Marking Unit
CAUTION
Do not touch the exposed face of the printheads. Surface contamination or minor damage can
destroy the printhead. Printheads must only be cleaned by a purge cycle.
Procedure
1. Perform dC965 Printhead Maintenance Cycle Test.
2. Empty the waste tray and reset waste tray count in the Call Closeout window in service
mode.
Drum
Materials:
• Cleaning cloth, PL 26.10 Item 6.
• Cleaning fluid, PL 26.10 Item 1.
CAUTION
Do not use anything sharp or abrasive on the drum as this will damage the drum surface.
Procedure
1. Enter dC612 and print TP 12 chase pages to clear ink from the drum.
2. Switch off the machine, GP 14.
3. Rotate the drum clockwise while cleaning it with a cleaning cloth dampened with cleaning
fluid.
4. Use a dull plastic edge to remove any solid ink from the drum.
5. Once the fault has been rectified, enter dC612 and print TP 14 to check that the stripper
blade is working correctly.
Transfix Roller
Materials:
• Cleaning cloth, PL 26.10 Item 6.
• Cleaning fluid, PL 26.10 Item 1.
Procedure
1. Switch off the machine, GP 14.
2. Clean the transfix roller, REP 10.1 with a cloth dampened with cleaning fluid.
Stripper Gate and Baffle
Materials:
• Cleaning cloth, PL 26.10 Item 6.
Procedure
WARNING
Take care during this procedure. The stripper blade is very sharp and can cause injury.
WARNING
Do not clean the stripper blade. The stripper blade is very sharp and can cause injury. If
the stripper blade is dirty a new blade must be installed.
1. Open the stripper gate and baffle assembly, GP 31.
2. If the stripper blade is dirty or damaged then install a new stripper blade, PL 10.12 Item 3.
3. Clean the rollers J PL 10.10 Item 1 and L PL 10.10 Item 2 with a cloth dampened with
water.
IOD
Materials:
• Cleaning cloth, PL 26.10 Item 6.
CAUTION
Do not use any liquid on the IOD sensor.
Procedure
1. Remove the abatement plenum, REP 91.36.
2. Only if the IOD appears contaminated should it be removed, REP 91.22.
3. Remove ink or debris from the gears and encoding wheel.
4. Manual rotate the motor to open the cover shield and reveal the sensor.
5. Figure 1, Gently clean the IOD sensor, with a dry, cleaning cloth.
6. Figure 1. Clean the cover shield using a dry cleaning cloth.
7. Reinstall the IOD assembly, REP 91.22.