February 2013
6-233
ColorQube® 9303 Family
dC131
General Procedures/Information
616-227 IR1a last bin
updated
Not displayed
IR1a last updated binId Range = 0 to 0 0
616-228 IR2a last bin
updated
Not displayed
IR2a last updated binId Range = 0 to 23 0
616-229 Display Snooze
Message
When the CCS instructs the
IME to enter Snooze mode, it
needs to remember that
snooze was initiated since the
IME does not report this mode.
When a new unit is detected,
the flag should be reset. Note
setting this NVM will not
induce snooze mode, it merely
determines whether the Status
is set for displaying the UI
message.
0 = IME not in snooze
mode
1 = IME in snooze
mode
Range = 0 to 1
0
616-230 RefurbModeNVM Indicates that the machine has
been refurbed, therefore the
activation date and CRU Install
dates are not be updated upon
completion of Install Wizard.
0 = Not refurbed
1 = Refurbed
Range = 0 to 1
0
616-232 powersaver fast
resume idletime
Defines time in "normal" mode
where system has been idle to
enabled transition into power
saver WITH fast resume set
The idle time in min-
utes before the
machine will enter
Low power with Fast
resume set
Range = 1 to 225
60
616-233 powersaver fast
resume in mode1
Defines time in "mode 1"
before transitioning to "mode
3" WITH fast resume set.
The idle time in min-
utes the machine will
remain in Low power
before entering Sleep
with Fast Resume set
Range = 0 to 225
120
616-234 UI system Time-
out value
UI system Timeout value Range = 15 to 3600 60
Table 20 CCS NVM ID 616-xxx
NVM ID NVM Name NVM Description Settings Default
616-235 RegDiff Regional Differentiator value Initially this will be
settable via DC131 -
however it must be
changed to RO once
the secure mecha
-
nism for setting this is
available.
NA_Classic = 1
NA_Enterprise = 2
XE_Classic = 3
XE_Enterprise = 4
DMO_Classic = 5
DMO_Enterprise = 6
Metered = 7
FX_Classic = 8
FX_Enterprise = 9
SR_Classic = 10
SR_Enterprise = 11
WW_Classic = 12
WW_Enterprise = 13
NA_XE_Classic = 14
NA_XE_Enterprise =
15
Factory = 63
1
616-236 Not displayed JBA Cost Control: Enable/Dis-
able
0 = Disable JBA Cost
Control1 = Enable
JBA Cost Control
0
616-238 UI System Time-
out Warning
Enabled
UI System Timeout Warning
Enabled / Disabled
0 = Disable1 =
Enable
1
616-240 Not displayed Tiered billing password (Pin
) Bik+2 tier
## ##
616-246 CheckVanillaRun-
Result
Check vanilla routine has been
executed on machine
0 = Unknown
1 = Pass
2 = Fail
Range = 0 to 255
0
Table 21 CCS NVM ID 617-xxx
NVM ID NVM Name NVM Description Settings Default
617-001 Not displayed -Fault Log Range = 0 to 0 0
617-002 faults displayed
on TTY
Range = 0 to 1 1
617-003 display faults Range = 0 to 1 1
617-004 Not displayed StapleMv Range = 0 to 0 0
617-005 Not displayed StapleMv Range = 0 to 256 0
Table 20 CCS NVM ID 616-xxx
NVM ID NVM Name NVM Description Settings Default