No.
(Addr.
Hex)
Name LCD Display Description Values Page
F7-04
(3E8)
<6> <7>
<8>
IP Address 4 IP Address 4
Sets the fourth most significant octet of network static IP
address.
Default: 20
Min.: 0
Max.: 255
–
F7-05
(3E9)
<8>
Subnet Mask 1 Subnet Mask 1 Sets the most significant octet of network static Subnet Mask.
Default: 255
Min.: 0
Max.: 255
–
F7-06
(3EA)
<8>
Subnet Mask 2 Subnet Mask 2
Sets the second most significant octet of network static Subnet
Mask.
Default: 255
Min.: 0
Max.: 255
–
F7-07
(3EB)
<8>
Subnet Mask 3 Subnet Mask 3
Sets the third most significant octet of network static Subnet
Mask.
Default: 255
Min.: 0
Max.: 255
–
F7-08
(3EC)
<8>
Subnet Mask 4 Subnet Mask 4
Sets the fourth most significant octet of network static Subnet
Mask.
Default: 0
Min.: 0
Max.: 255
–
F7-09
(3ED)
<8>
Gateway Address 1 Gateway IP Add 1 Sets the most significant octet of network Gateway address.
Default: 192
Min.: 0
Max.: 255
–
F7-10
(3EE)
<8>
Gateway Address 2 Gateway IP Add 2
Sets the second most significant octet of network Gateway
address.
Default: 168
Min.: 0
Max.: 255
–
F7-11
(3EF)
<8>
Gateway Address 3 Gateway IP Add 3
Sets the third most significant octet of network Gateway
address.
Default: 1
Min.: 0
Max.: 255
–
F7-12
(3E0)
<8>
Gateway Address 4 Gateway IP Add 4
Sets the fourth most significant octet of network Gateway
address.
Default: 1
Min.: 0
Max.: 255
–
F7-13
(3F1)
Address Mode at Startup
IP Add Mode Sel
0: User Defined
1: BOOTP
2: DHCP
Select the option address setting method
0: Static
<7> <8>
1: BOOTP
2: DHCP
Default: 2
Range: 0 to 2
–
F7-14
(3F2)
Duplex Mode Selection
Duplex Select
0: Half/Half
1: Auto/Auto
2: Full/Full
3: Half/Auto
4: Half/Full
5: Auto/Half
6: Auto/Full
7: Full/Half
8: Full/Auto
Selects duplex mode setting.
0: Half Duplex forced (Both ports)
<9>
1: Auto Negotiate (Both ports)
2: Full Duplex forced (Both ports)
<9>
3: Half (Port 1) / Auto (Port 2)
<3>
4: Half (Port 1) / Full (Port 2)
<3>
5: Auto (Port 1) / Half (Port 2)
<3>
6: Auto (Port 1) / Full (Port 2)
<3>
7: Full (Port 1) / Half (Port 2)
<3>
8: Full (Port 1) / Auto (Port 2)
<3>
Default: 1
Range: 0 to 8
–
F7-15
(3F3)
<9>
Communication Speed
Selection
Baud Rate
10: 10/10 Mbps
100: 100/100 Mbps
101: 10/100 Mbps
102: 100/10 Mbps
Sets the communication speed
10: 10 Mbps
100: 100 Mbps
101: 10 (Port 1) / 100 Mbps (Port 2)
<3>
102: 100 (Port 1) / 10 Mbps (Port 2)
<3>
Default: 10
Range: 10, 100,
101, 102
–
F7-16
(3F4)
Communication Loss
Timeout
CommLoss Tout
Sets the timeout value for communication loss detection.
Setting this parameter to 0.0 disables the connection timeout.
Default: 0.0 s
<10>
Min.: 0.0
Max.: 30.0
–
F7-17
(3F5)
EtherNet/IP Speed
Scaling Factor
EN Speed Scale
Sets the scaling factor for the speed monitor in EtherNet/IP
Class ID 2AH Object.
Default: 0
Min.: -15
Max.: 15
–
F7-18
(3F6)
EtherNet/IP Current
Scaling Factor
EN Current Scale
Sets the scaling factor for the output current monitor in
EtherNet/IP Class ID 2AH Object.
Default: 0
Min.: -15
Max.: 15
–
F7-19
(3F7)
EtherNet/IP Torque
Scaling Factor
EN Torque Scale
Sets the scaling factor for the torque monitor in EtherNet/IP
Class ID 2AH Object.
Default: 0
Min.: -15
Max.: 15
–
B.6 F: Communication Option Parameters
300