Chapter 22 IPv6
GS1920v2 Series User’s Guide
136
22.8.1 Add/Edit IPv6 Neighbor
Use this screen to create a static IPv6 neighbor entry. Click Add/Edit, or select an entry and click Add/
Edit in the SYSTEM > IPv6 > IPv6 Neighbor Setup screen to display this screen.
Figure 94 SYSTEM > IPv6 > IPv6 Neighbor Setup > Add/Edit
The following table describes the labels in this screen.
Neighbor
Address
This field displays the IPv6 address of the neighboring device which can be reached through the
interface.
MAC This field displays the MAC address of the neighboring device which can be reached through the
interface.
Select an entry’s check box to select a specific entry. Otherwise, select the check box in the table
heading row to select all entries.
Add/Edit Click Add/Edit to add a new entry or edit a selected one.
Delete Click Delete to remove the selected entries.
Table 48 SYSTEM > IPv6 > IPv6 Neighbor Setup (continued)
LABEL DESCRIPTION
Table 49 SYSTEM > IPv6 > IPv6 Neighbor Setup > Add/Edit
LABEL DESCRIPTION
Interface Select the type of IPv6 interface for which you want to configure. The Switch supports the VLAN
interface type for IPv6 at the time of writing.
Interface ID Specify a unique identification number (from 1 to 4094) for the interface.
A static IPv6 neighbor entry displays in the MONITOR > IPv6 Neighbor Table screen only when the
interface ID is also created in the SYSTEM > Interface Setup screen.
To have IPv6 function properly, you should configure a static VLAN with the same ID number in the
SWITCHING > VLAN screens.
Neighbor
Address
Specify the IPv6 address of the neighboring device which can be reached through the interface.
MAC Specify the MAC address of the neighboring device which can be reached through the
interface.
Apply Click Apply to save your changes to the Switch’s run-time memory. The Switch loses these
changes if it is turned off or loses power, so use the Save link on the top navigation panel to save
your changes to the non-volatile memory when you are done configuring.
Clear Click Clear to clear the fields to the factory defaults.