Parameters 231
Clearing... Clearing in progress. 1
16.07 USER SET SEL
Enables the save and restoration of up to 50 custom
sets of parameter settings.
The set that was in use before powering down the
drive is in use after the next power-up.
Note:
Any parameter changes made after loading a user
set are not automatically stored into the loaded
set. Changes must be saved using this parameter.
This parameter cannot be changed while the drive
is running.
0 / enum
-1...1050 User set selection - / 1
16.08 USER SET LOG
Shows the status of the user parameter sets (see
parameter 16.07 USER SET SEL).
This parameter is read-only.
N/A /
Pb
N/A No user sets are saved. 0
Loading A user set is loaded. 1
Saving A user set is saved. 2
Faulted Invalid or empty parameter set. 4
Set1 IO act User parameter set 1 is selected by parameters
16.09 and 16.10.
8
Set2 IO act User parameter set 2 is selected by parameters
16.09 and 16.10.
16
Set3 IO act User parameter set 3 is selected by parameters
16.09 and 16.10.
32
Set4 IO act User parameter set 4 is selected by parameters
16.09 and 16.10.
64
Set1 par act User parameter set 1 is loaded using parameter
16.07.
128
Set2 par act User parameter set 2 is loaded using parameter
16.07.
256
Set3 par act User parameter set 3 is loaded using parameter
16.07.
512
Set4 par act User parameter set 4 is loaded using parameter
16.07.
1024
No. Bit/Name/Value/
Range
Description Def/Type
FbEq
(16b/32b)

Table of Contents