310 Fault tracing
0306
LICENSING Drive internal fault
Note: This fault cannot be
reset.
Contact your local ABB
representative.
0307
DEFAULT FILE Drive internal fault
Note: This fault cannot be
reset.
Contact your local ABB
representative.
0308
APPL FILE PAR
CONF
Corrupted application file
Note: This fault cannot be
reset.
Reload the application.
If the fault is still active, contact
your local ABB representative.
0309
APPL LOADING Application file
incompatible or corrupted.
Note: This fault cannot be
reset.
Check the fault logger for a fault
code extension. See appropriate
actions for each extension below.
Fault code
extension: 8
Template used in the
application incompatible
with drive firmware.
Change the template of the
application in DriveSPC.
Fault code
extension: 10
Parameters defined in the
application conflict with
existing drive parameters.
Check the application for conflicting
parameters.
Fault code
extension: 35
Application memory full. Contact your local ABB
representative.
Fault code
extension: Other
Corrupted application file Reload application.
If fault is still active, contact your
local ABB representative.
0310
USERSET LOAD Loading of user set is not
successfully completed
because:
• requested user set does
not exist
• user set is not
compatible with the drive
program
• drive is switched off
during loading.
Reload.
0311
USERSET SAVE User set is not saved
because of memory
corruption.
Contact your local ABB
representative.
0312
UFF OVERSIZE UFF file is too big. Contact your local ABB
representative.
0313
UFF EOF UFF file structure failure Contact your local ABB
representative.
Code Fault Cause What to do