Fault tracing 311
0314
TECH LIB
INTERFACE
Incompatible firmware
interface
Note: This fault cannot be
reset.
Contact your local ABB
representative.
0315
RESTORE FILE Restoration of backed-up
parameters failed.
Contact your local ABB
representative.
0316
DAPS MISMATCH Mismatch between JCU
Control Unit firmware and
power unit logic versions.
Contact your local ABB
representative.
0317
SOLUTION FAULT Fault generated by
function block
SOLUTION_FAULT in the
application program.
Check the usage of the
SOLUTION_FAULT block in the
application program.
601
SPEED MATCH
05.02 LIFT FW bit 0
Speed error is higher than
defined with parameter
81.02 SPD STD DEV LVL
in the steady state or
defined with parameter
81.03 SPD RMP DEV LVL
in the ramp state, and the
time delay defined with
parameter 81.04 SPEED
MATCH DLY has elapsed.
The speed controller is not
following the speed
reference.
Check ramp times.
Check torque and current limit
settings.
602
TORQUE PROVE
05.02 LIFT FW bit 1
Drive was not able to
provide sufficient torque
during a torque proving
sequence.
Control magnetising time is
too low.
Check the motor and motor cables.
603
BRAKE SLIP
05.02 LIFT FW bit 2
Brake slipped while a
torque proving sequence
was taking place.
Check the brakes.
Check whether the brakes are
slipping in the brake closed
condition.
Code Fault Cause What to do