2
E-STOP and shutdown
The E-STOP is used for emergency program shut down by turning
off the servo motors.
NOTICE
On some machines the E-STOP does not shut down the spindle
motor. On such machines the spindle motor must always be
manually stopped using the spindle switch to stop the motor,
and the cutting tool.
When the E-STOP button is pressed, the servo
motors are stopped. On some machines it does
not shut down the spindle motor.
When the STOP key is pressed once, the servo
motors pause, but are still active. All axes are
locked, and can not be moved.
The program can now either continue by
pressing the GO key, or stopped by pressing the
STOP key a second time.
Shutting down the system is done by using the Shutdown soft key.
Press the Shutdown soft key to power down the
control, so that the main switch can be turned off
Wait for the indication that it is OK to turn power
off
Press the Restart soft key to reboot the control,
shutting down and subsequently starting back up
Press the Cancel soft key to cancel and exit the
shut down procedure
NOTICE
Always shutdown the control before turning power off to the
machine.
Refer to the builder's instructions for additional information on
turning power off.
Emergency stop (E-STOP)
Press E-STOP to take all axes servos offline
This ends all machine movement, and allows the
operator to manually move the tool out of the
way
To reset the E-STOP
Turn the rotary switch clockwise in the direction of the arrows
The switch pops outward and is reset
Resetting E-STOP does not reactivate the servos.