DRO mode | Diameter/Radius mode
4.8 Diameter/Radius mode
The system can treat the values for the X-Axis as either diameter
or radius values. The current mode activated in the system is
indicated in the top status bar of the screen, as well as next to the
position value of the X-Axis in the DRO position display.
When the active mode is Diameter, the symbol "Ø" will be
displayed in these areas. When the active mode is Radius, the
symbol is not displayed in these areas. Depending on user
preference, or on engineering drawing types, it may be necessary
to change the active system mode.
Refer to Section 11 for details on changing the active mode.