Parameters U511 User’s Manual
4-76 Aerotech, Inc. Version 1.1
Table 4-57. Settings for Parameter x48
Param # Axis # Range Default
148 1 0% to 100% 30.0000 %
248 2 0% to 100% 30.0000 %
348 3 0% to 100% 30.0000 %
448 4 0% to 100% 30.0000 %
If the value of parameter x48 is set to 100%, an RMS current trap will never be
generated for the associated axis.
This parameter is used in conjunction with parameter x49 to determine RMS
current level faults.