Symptom : creation of a new administrator to manage OpenTouch. No way to connect the opentouch 
 
 
 
Solution: 
The administrator has to be created at 8770 and OT sides 
12.7.16 No way to synchronize new Oxe 
 
Symptom : Creation of new oxe no way to synchronize Oxe, error while synchonizing MIB ,error setup error 
Solution : check the adfexc password, check the network subnetwork of Oxe in 8770, check that Main FQDN 
of oxe is matching with Main IP address 
12.7.17 No way to manage Oxe 
 
Symptom : Oxe management access from 8770 is prohibited 
Solution : check the OT configuration 
 System Service/Security/Administrator 
 Application : 8770 
 Select Delegate authentication 
 
12.7.18 Error message « cmsexception » 
 
Symptom : UUM : user created by UUM 8770 are not readable from OpenTouch 8770 configuration nor 
WBM 
MyIC connection ICSlocator_error in mpc logs 
Diagnosis : right of admin are not sufficient 
Solution check cms logs for more information 
 
12.7.19 Error message « error-bad-parameter-value » 
 
Symptom : system returns  
Diagnosis : check OT /logs/cms/traces.log 
12.7.20 Error message “The amount of links between users and devices is greater than 0” 
Symptom : Error in 8770 Users Management : The amount of links between users and devices is greater 
than 0 
Diagnosis : Message : “BAD LICENSE FILE - Can't find ICE_USER_DEVICE_ASSOCIATION license. 
Please update your license file.“ in cms log 
ICE_USER_DEVICE_ASSOCIATION missing in OT 1.1 license. Actis 16.5.1 issue. 
Solution : New license provided to BP