EasyManua.ls Logo

AMP EFI MS3Pro - Detection

AMP EFI MS3Pro
305 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.3 Ignition Settings 7 ADDITIONAL ITEMS: BEYOND BASIC FUEL AND IGNITION CONTROL
Safe Mode: use knock retard, but keep the advance below that which caused knock. This backs the
advance 1 small step back and leaves it at that until TPS or MAP changes - or knock comes back. This
is "safe mode" scheme is the safest thing for a DIY set-up.
Aggressive Mode: use knock retard, but keep advance at threshold of knock occurring. That is, the
program advances (up to the timing table value) if it doesn’t see knock, and retards if does see knock.
The difference from safe mode is that the timing can be advance all the way to the table value after
knock, not just up to one step below knock. This may result in the knock returning, in which case the
timing is retarded again, then advanced slowly, and so on. This approach is also called closed loop
knock control.
Input type:
On/Off: basic on/off "knock" or "no-knock" external input.
Analogue: external analogue input proportional to knock signal level
Internal: internal knock module.
Input pin (only for on/off) Which input pin the external module is connected to. Note: If using the Knock In
1 or Knock In 2 pins, set the input type to “internal” and this will automatically select the dedicated
knock pins.
Knock Indicated By (only for On/off) The logic input level. i.e. when set to "low" then a 0V signal means
there is knock. GM external knock modules fall into this categories.
Pullup/down on input (only for On/off) Whether an internal pull-resistor should be applied. When using the
normal digital input modes, this should be set to “None.
Input pin (only for Analogue) Which analogue input pin the external module is connected to.
Window Sample Type (only for Analogue) Either read single analogue value at end knock window or peak
detect.
Window Output (only for Analogue) Optional digital output for knock window signal.
Monitor Per Cylinder Enables using different knock thresholds for each cylinder. This requires sequential
fueling and/or coil on plug mode to be enabled.
Control Per Cylinder This allows knock retard to only be applied to the cylinder that is knocking. If turned
off, knock control is applied to all cylinders.
DEBUG data Adds per-cylinder knock measurements to datalogging.
7.3.7.2 Detection
Knock Count (knocks): number of knock events detected before control is started
Knock Ignored above MAP (kPa): no knock retard is implemented above this MAP
RPM window low (rpm): knock control is implemented above this rpm
RPM window high (rpm): knock control is implemented below this rpm. This upper limit is desirable as valve
train noise will typically mask out the knock sensor signal at higher rpm which could cause false reports of
knock.
Ignore During Launch / Flatshift: Flat shift or launch rev limiting with a spark cut can cause enough noise
to cause false knock readings on some engines. This setting disables detection when the launch or flat shift
rev limiter is active.
AMP EFI MS3Pro manual version 1.202, firmware 1.5.0, 4/21/2017 Page 173

Table of Contents