3.3.1.14. In-band Emissions for non-allocated RB
3.3.1.14.1. MT8820C
[Acceptable Value Setting]
1. [PCC/SCC] Execute MOD_AVG 20 to set the average count of Modulation Analysis to 20 times.
2. [PCC/SCC] Execute TP_INBANDE_GEN_D -57.0 to set General Pass/Fail judgment of TX1 – IBE/LEAK @
0dBm.
[Measurements]
3. [PCC/SCC] Execute TESTPRM TX_0DBM to set Test Parameter to TX1 – IBE/LEAK @ 0 dBm.
4. [PCC/SCC] Set UL RMC – Number of RB and Starting RB.
5. [PCC/SCC] Execute SWP to measure the Modulation Analysis.
6. [PCC/SCC] Execute INBANDE_GEN? MAX to read the In–Band Emissions (General) measurement result.
7. [PCC/SCC] Execute INBANDE_IMG? MAX to read the In–Band Emissions (IQ Image) measurement result.
8. [PCC/SCC] Execute INBANDE_LEAK? MAX to read the In–Band Emissions (Carrier Leakage) measurement
result.
9. [PCC/SCC] Execute INBANDEPASS? to check that the In–Band Emissions Pass/Fail judgment is Pass.
10. [PCC/SCC] Execute TESTPRM TX_M30DBM to set Test Parameter to TX1 – IBE/LEAK @ –30 dBm.
11. Execute steps 4 to 9.
12. [PCC/SCC] Execute TESTPRM TX_M40DBM_Q_P to set Test Parameter to TX1 – EVM/IBE/LEAK @ –40 dBm
(QPSK/PartialRB).
13. Execute steps 4 to 9.
3.3.1.14.2. MT8821C
[Acceptable Value Setting]
1. Execute MOD_AVG 20 to set the average count of Modulation Analysis to 20 times.
2. Execute TP_INBANDE_GEN_D -57.0 to set General Pass/Fail judgment of TX1 – IBE/LEAK @ 0dBm.
[Measurements]
3. Execute TESTPRM TX_0DBM to set Test Parameter to TX1 – IBE/LEAK @ 0 dBm.
4. Set PCC and SCC–1 UL RMC – Number of RB and Starting RB.
5. Execute SWP to measure the Modulation Analysis.
6. Execute INBANDE_GEN? MAX,PCC to read the PCC In–Band Emissions (General) measurement result.
7. Execute INBANDE_IMG? MAX,PCC to read the PCC In–Band Emissions (IQ Image) measurement result.
8. Execute INBANDE_LEAK? MAX,PCC to read the PCC In–Band Emissions (Carrier Leakage) measurement
result.
9. Execute INBANDEPASS? PCC to check that the PCC In–Band Emissions Pass/Fail judgment is Pass.
10. Execute INBANDE_GEN? MAX,SCC1 to read the SCC -1In–Band Emissions (General) measurement result.
11. Execute INBANDE_IMG? MAX,SCC1 to read the SCC-1 In–Band Emissions (IQ Image) measurement result.
12. Execute INBANDE_LEAK? MAX,SCC1 to read the SCC-1 In–Band Emissions (Carrier Leak) measurement
result.
13. Execute INBANDEPASS? SCC1 to check that the SCC–1 In–Band Emissions Pass/Fail judgment is Pass.
14. Execute TESTPRM TX_M30DBM to set Test Parameter to TX1 – IBE/LEAK @ –30 dBm.
15. Execute steps 4 to 13.
16. Execute TESTPRM TX_M40DBM_Q_P to set Test Parameter to TX1 – EVM/IBE/LEAK @ –40 dBm
(QPSK/PartialRB).
17. Execute steps 4 to 13.

Table of Contents