142
3.3.2.14. In-band emissions for non allocated RB for CA (intra-band contiguous DL CA and UL CA)
(6.5.2A.3-1)
3.3.2.14.1. MT8820C
This measurement item is not supported by the MT8820C.
Refer to Table 3.3–1.
3.3.2.14.2. MT8821C
This subsection describes an example of intra–band measurement.
Example: PCC N
RB
= 100, SCC N
RB
= 50, N
RB_alloc
= 12, Modulation = QPSK
PCC and SCC RB allocations (L
CRB
@RB
start
) are P_12@0 and S_0@0, respectively
For Intra–band measurement, the Carrier Leakage Frequency Parameter must be set properly set before the start
of measurement sequence. For more information, see Annex B.2.
[Carrier Leakage Frequency Setting]
1. Execute IBEM_CLFR CFR to set Carrier Leakage Frequency to at Carrier Frequency Center.
[Pass/Fail evaluation limits value setting]
2. Execute MOD_AVG 20 to set the average count of Modulation Analysis to 20 times.
3. Execute TP_INBANDE_GEN_A -29.2 (or TP_INBANDE_GEN_A -29.2, PCC) to set General Pass/Fail judgment of
TX1 - IBE/LEAK @ 0/–30/–40 dBm for PCC.
4. Execute TP_INBANDE_GEN_B -24.2 (or TP_INBANDE_GEN_B -24.2, PCC) to set General Pass/Fail judgment of
TX1 - IBE/LEAK @ 0/–30/–40 dBm for PCC.
5. Execute TP_INBANDE_GEN_C -2.2 (or TP_INBANDE_GEN_C -2.2, PCC) to set General Pass/Fail judgment of
TX1 - IBE/LEAK @ 0/–30/–40 dBm for PCC.
6. Execute TP_INBANDE_GEN_D -56.2 (or TP_INBANDE_GEN_D -56.2, PCC) to set General Pass/Fail judgment of
TX1 - IBE/LEAK @ 0/–30/–40 dBm for PCC.
7. Execute TP_INBANDE_IMG –24.2 (or TP_INBANDE_IMG –24.2, PCC) to set General Pass/Fail judgment of TX1
- IBE/LEAK @ 0/–30/–40 dBm for PCC.
8. Execute TP_INBANDE_LEAK_0DBM –24.2 (or TP_INBANDE_LEAK_0DBM –24.2, PCC) to set General Pass/Fail
judgment of TX1 – IBE/LEAK @ 0 dBm for PCC.
9. Execute TP_INBANDE_LEAK_M30DBM –19.2 (or TP_INBANDE_LEAK_M30DBM –19.2, PCC) to set General
Pass/Fail judgment of TX1 – IBE/LEAK @ –30 dBm for PCC.
10. Execute TP_INBANDE_LEAK_M40DBM –9.2 (or TP_INBANDE_LEAK_M40DBM –9.2, PCC) to set General
Pass/Fail judgment of TX1 – IBE/LEAK @ –40 dBm for PCC.
11. Execute TP_INBANDE_GEN_A -29.2, SCC1 to set General Pass/Fail judgment of TX1 – IBE/LEAK @ 0/–30/–40
dBm for SCC–1.
12. Execute TP_INBANDE_GEN_B -24.2, SCC1 to set General Pass/Fail judgment of TX1 – IBE/LEAK @ 0/–30/–40
dBm for SCC–1.
13. Execute TP_INBANDE_GEN_C -2.2, SCC1 to set General Pass/Fail judgment of TX1 – IBE/LEAK @ 0/–30/–40
dBm for SCC–1.
14. Execute TP_INBANDE_GEN_D -57.0, SCC1 to set General Pass/Fail judgment of TX1 – IBE/LEAK @ 0/–30/–40
dBm for SCC–1.
15. Execute TP_INBANDE_IMG –24.2, SCC1 to set General Pass/Fail judgment of TX1 – IBE/LEAK @ 0/–30/–40
dBm for SCC–1.
16. Execute TP_INBANDE_LEAK_0DBM –24.2, SCC1 to set General Pass/Fail judgment of TX1 – IBE/LEAK @ 0
dBm for SCC–1.
17. Execute TP_INBANDE_LEAK_M30DBM –19.2, SCC1 to set General Pass/Fail judgment of TX1 – IBE/LEAK @ –
30 dBm for SCC–1.
18. Execute TP_INBANDE_LEAK_M40DBM –9.2, SCC1 to set General Pass/Fail judgment of TX1 – IBE/LEAK @ –40
dBm for SCC–1.
[Measurements for test configuration of first example]
19. Execute TESTPRM TX_0DBM to set Test Parameter to TX1 – IBE/LEAK @ 0 dBm.
20. Execute ULRMC_RB 12 to set Common Parameter – UL RMC – Number of RB to 12.
(For other Configuration ID setting, set Common Parameter – UL RMC – Number of RB and Starting RB
according to TS36.521–1 Table 6.5.2A.3.1.4.1–1.)
21. Execute ULRMC_RB_SCC1 0 to set Common Parameter – SCC-1 – UL RMC - Number of RB to 0.
22. Execute SWP to measure the Modulation Analysis.
23. Execute INBANDE_GEN? MAX (or INBANDE_GEN? MAX, PCC) to read the In–band Emissions (General)
measurement result of PCC (allocated component carrier).
24. Execute INBANDE_IMG? MAX (or INBANDE_IMG? MAX, PCC) to read the In–band Emissions (IQ Image)