143
measurement result of PCC (allocated component carrier).
25. Execute INBANDE_LEAK? MAX (or INBANDE_LEAK? MAX, PCC) to read the In–band Emissions (Carrier
Leakage) measurement result of PCC (allocated component carrier).
26. Execute INBANDEPASS? (or INBANDEPASS? PCC) to check that the In–band Emissions Pass/Fail judgment of
PCC (allocated component carrier) is Pass.
27. Execute INBANDE_GEN? MAX, SCC1 to read the In–band Emissions (General) measurement result of SCC-1
(not allocated component carrier).
28. Execute INBANDE_IMG? MAX, SCC1 to read the In–band Emissions (IQ Image) measurement result of SCC-1
(not allocated component carrier).
29. Execute INBANDE_LEAK? MAX, SCC1 to read the In–band Emissions (Carrier Leakage) measurement result
of SCC-1 (not allocated component carrier).
30. Execute INBANDEPASS? SCC1 to check that the In–band Emissions Pass/Fail judgment of SCC-1 (not
allocated component carrier) is Pass.
31. Execute TESTPRM TX_M30DBM to set Test Parameter to TX1 – IBE/LEAK @ –30 dBm.
32. Execute steps 20 to 30.
33. Execute TESTPRM TX_M40DBM_Q_P to set Test Parameter to TX1 – EVM/IBE/LEAK @ –40 dBm
(QPSK/PartialRB).
34. Execute steps 20 to 30.