Measurement Results
109
1. Power left in battery This indicates how much power there is left in the battery. When
the battery indicator is completely white the battery is fully charged
and when the battery indicator is completely black the battery has
less than 8% charge left.
Communication
symbol
ToolsTalk communication selected
Focus 2000 / Power Focus 2000 communication selected.
DS serial communication selected.
DS infrared communication selected.
Power Focus 3000 serial communication selected.
Power Focus 3000 infrared communication selected.
Barcode communication selected.
PowerMac communication selected.
2. Scale X-vice The values and unit for the X-scale.
3. Scale Y-vice left The values and unit for the Y-scale.
4. Scale Y-vice right Angle information when the parameter includes torque and angle
(time).
5. Angle start point This is the torque level, defined in the configuration where the angle
starts counting.
6. Peak point The level where the torque is at maximum and where it stops
counting.
7. Peak torque The highest torque value during the tightening operation. When the
result is outside the acceptance interval, the text flashes.
8. Measured angle Angle outside the accepted interval flashes in the same way as the
torque.
9. Softkey text The softkey text represents the main menus of the current
programming tree and is operated by the 5 buttons located below
the display. Each softkey field displays the functionality of each
button.