Programming
64
3. Controller Used in tool calibration to select the type of controller to calibrate.
There are 6 types:
1. None
2. Other controller
3. F2000/PF2000
4. DS
5. PF3000
6. Power Macs
• “None” is used for handheld or non-controlled tools.
• ”Other controller” is used for unknown or unsupported
controlled tools. Manual input of controller tightening values is
required.
• “F2000/PF2000” is used for Focus 2000 and Power Focus
2000 controlled tools. If selected, controller tightening values
are automatically received from the controller after each
tightening operation.
• “DS” is used for DS controlled tools. If selected, no tightening
values are read from the controller after each tightening.
• “PF3000” is used for Power Focus 3000 controlled tools. If
selected, controller tightening values are automatically
received from the controller after each tightening. No
tightening values are read from controller for “PF3000” model
“Tensor DS”.
• “PowerMacs” is used for PowerMac controlled tools. If
selected, controller tightening values are automatically
received from the controller after each tightening operation.
4. Calibration torque Used in “Other controller”, “F2000/PF2000”, “PF3000” or
“PowerMac” tool calibration and corresponds to the calibration
torque in the unknown or unsupported controlled tools (Other
controller) or the F2000/PF2000 controller (F2000/PF2000),
PF3000 controller (PF3000) or PowerMac controller
(PowerMac).