Chapter 10. List of Communication Data
Bank Item RAM address EEPROM address RAM EEPROM Decimal
point
Notes
Decimal Hexa-
decimal
Decimal Hexa-
decimal
Read Write Read Write
Event
configura-
tion
Internal event 1 delay time unit 5808 16B0 22192 56B0 −
(Reserved for future use.) 5809 16B1 22193 56B1
−
Internal event 2 operation type 5810 16B2 22194 56B2 −
Internal event 2 direct/reverse 5811 16B3 22195 56B3 −
Internal event 2 standby 5812 16B4 22196 56B4 −
Internal event 2 event state at READY 5813 16B5 22197 56B5 −
(Reserved for future use.) 5814 16B6 22198 56B6
−
Internal event 2 alarm OR 5815 16B7 22199 56B7 −
Internal event 2 special OFF setup 5816 16B8 22200 56B8 −
Internal event 2 delay time unit 5817 16B9 22201 56B9 −
(Reserved for future use.) 5818 16BA 22202 56BA
−
Internal event 3 operation type 5819 16BB 22203 56BB −
Internal event 3 direct/reverse 5820 16BC 22204 56BC −
Internal event 3 standby 5821 16BD 22205 56BD −
Internal event 3 event state at READY 5822 16BE 22206 56BE −
(Reserved for future use.) 5823 16BF 22207 56BF
−
Internal event 3 alarm OR 5824 16C0 22208 56C0 −
Internal event 3 special OFF setup 5825 16C1 22209 56C1 −
Internal event 3 delay time unit 5826 16C2 22210 56C2 −
(Reserved for future use.) 5827 16C3 22211 56C3
−
Internal event 4 operation type 5828 16C4 22212 56C4 −
Internal event 4 direct/reverse 5829 16C5 22213 56C5 −
Internal event 4 standby 5830 16C6 22214 56C6 −
Internal event 4 event state at READY 5831 16C7 22215 56C7 −
(Reserved for future use.) 5832 16C8 22216 56C8
−
Internal event 4 alarm OR 5833 16C9 22217 56C9 −
Internal event 4 special OFF setup 5834 16CA 22218 56CA −
Internal event 4 delay time unit 5835 16CB 22219 56CB −
(Reserved for future use.) 5836 16CC 22220 56CC
−
Internal event 5 operation type 5837 16CD 22221 56CD −
Internal event 5 direct/reverse 5838 16CE 22222 56CE −
Internal event 5 standby 5839 16CF 22223 56CF −
Internal event 5 event state at READY 5840 16D0 22224 56D0 −
(Reserved for future use.) 5841 16D1 22225 56D1
−
Internal event 5 alarm OR 5842 16D2 22226 56D2 −
Internal event 5 special OFF setup 5843 16D3 22227 56D3 −
Internal event 5 delay time unit 5844 16D4 22228 56D4 −
(Reserved for future use.) 5845 16D5 22229 56D5
−
Parameter
Control method
6001 1771 22385 5771 −
MV low limit at AT 6002 1772 22386 5772 1
MV high limit at AT 6003 1773 22387 5773 1
ON/OFF control differential 6004 1774 22388 5774 P
ON/OFF control operating point offset 6005 1775 22389 5775 P
PV filter 6006 1776 22390 5776 1
PV ratio 6007 1777 22391 5777 3
PV bias 6008 1778 22392 5778 P
(Reserved for future use.) 6009 1779 22393 5779
1
(Reserved for future use.) 6010 177A 22394 577A
3