Chapter 5: Routine Operational Procedures
Operators & Maintenance Manual GENIUS Compact Version UK 0.1 © BESTnv
BESTnv Industrial Research BV, Marinus van Meelweg 20, 5657 EN, EINDHOVEN, THE NETHERLANDS
General tel. +31 (40) 292 2622 - Service tel. +31 (40) 292 2620 - Fax. +31 (40) 292 2633 - Email: service.BESTnv@bestnv.com
5.- Adjust the position of the Accept Chute
- Loosen the necessary screws and handles and move the Chute closer to or further from the belt.
The angle hardly ever needs to be changed, and this should only be done by an experienced service
engineer from BESTnv.
- Put a number of typical good product objects on the running belt (with sorting or valves switched off).
If any objects fall into the reject chute, please move the accept chute closer to the belt until all objects
reach the accept chute.
Keep in mind the following rules:
- The accept chute should be moved as far away from the belt as possible (without having
accept going into the reject chute), to minimize the chance of getting reject in the accept.
6.-
Adjust position of Ejection Unit
- Loosen the necessary screws and handles and move the ejection unit upwards or downwards.
The angle hardly ever needs to be changed, and this should only be done by an experienced service
engineer from BESTnv.
Keep in mind the following rules:
- The ejection unit should be as close to the belt as possible, while still allowing the product
to pass between the ejection unit and the belt.
- A distance of 20 mm is ideal to minimize the false reject due to the width of the blast zone.
- Go to the Reject unit menu and enter the settings of both Accept chute and Ejection unit.
These data are just to have reference values when necessary. Changing them will not change the position
of reject unit or accept chute, that must be done manually.