104 User Manual Synertia® RF Generator
The information contained in this manual is subject to change by Comet Yxlon without prior notice.
(32 bit)
With this command the RF
output can be switched on or off
and revoked alarms (errors) can
be cleared.
The RF output is switched off.
The RF output is switched on.
(errors) are
" Power Control
With this command the control
mode of the unit can be selected.
It can work either in control
mode forward power, load
power or external process.
power”
The forward power of the
generator is controlled by the set
point for the internal power
control (see parameter 1206
“Power set point”).
The load power (load power =
forward power
- reflected
power) is controlled by the set
point for the internal power
control
(see parameter 1206 “Power set
point”).