104 User Manual Synertia® RF Generator
The information contained in this manual is subject to change by Comet Yxlon without prior notice.
Parameter
No.
Parameter
Name
Example
Value
Unit
Type
Enum
Values
Comment /
Description
Control
1001
Command
int
(32 bit)
With this command the RF
output can be switched on or off
and revoked alarms (errors) can
be cleared.
0
“RF off”
The RF output is switched off.
1
“RF on
The RF output is switched on.
9
“Reset Errors”
Revoked alarms
(errors) are
cleared.
Settings
" Power Control
1201
Control
mode
int (32 bit)
With this command the control
mode of the unit can be selected.
It can work either in control
mode forward power, load
power or external process.
0
“Forward
power”
The forward power of the
generator is controlled by the set
point for the internal power
control (see parameter 1206
“Power set point”).
1
“Load Power”
The load power (load power =
forward power
- reflected
power) is controlled by the set
point for the internal power
control
(see parameter 1206 “Power set
point”).