Page #155 background imageLoading...
Page #155 background image
155
4.4.17 Loop Detection Configuration
To set up Loop Detection function, select the option Loop Detection Configuration from the
Switch Management menu and then the following screen page appears.
Loop Detection: Enable or disable Loop Detection function.
Detection Interval: Specify the time interval of performing Loop Detection. The maximum time
interval is 180 seconds.
Looped port unlock-interval: Specify the time interval of unlocking looped ports. The maximum
time interval is 1440 minutes.
VLAN ID: Specify the VLANs where Loop Detection will be performed.
Port 1~26: Enable or disabled Loop Detection function on the specific port(s).