Enter/Exit Programming Mode GS1 DataBar
TM
 Expanded
104
Cobalto™  CO5300 Scanner
GS1 DataBar Expanded Set Length 2
This feature specifies one of the bar code lengths for GS1 DataBar Expanded Length 
Control
. Length 2 is the maximum label length if in Variable Length Mode, or the second 
fixed length if in 
Fixed Length Mode. Length includes the bar code’s data characters only.
The length can be set from 1 to 74 characters. A setting of 00 specifies to ignore this length 
(on
ly one fixed length). See 
"Set Length 2" on page 241 for more detailed programming 
instructions.
Select GS1 DataBar Expanded
 Set Length 2 Setting
To configure this feature, scan the ENTER/EXIT bar 
cod
e above, then the bar code at left followed by dig-
its from the Alphanumeric characters in 
Appendix D, 
Keypad
 representing your desired character(s). End 
by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code 
to abort 
and not save the entry string. You can then start 
again at the beginning.
CANCEL
DEFAULT
74 = Length 2 is 74 Characters
$CXBL2
~