Enter/Exit Programming Mode Code 128
122
Cobalto™ CO5300 Scanner
Expand Code 128 to Code 39
This feature enables/disables expansion of Code 128 labels to Code 39 labels. When enabled,
the label identifier for a Code 128 label shall be set to Code 39 and all Code 39 formatting
control shall be applied to the label.
DEFAULT
Code 128 to Code 39 = Don’t Expand
Code 128 to Code 39 = Expand
Code 128 Check Character Transmission
Enable this option to transmit the check character along with Code 128 bar code data.
DEFAULT
Code 128 Check Character Transmission = Don’t Send
Code 128 Check Character
Transmission = Send
$CC8C300
$CC8C301
$CC8CT00
$CC8CT01